1. Primary Organic Matter Reservoir
- Materials: high-density polyethylene
- Volume 200 L
- Drain valve
- Low level detector
- Variable speed marine propeller agitator
2. Feed pump
- Variable speed peristaltic pump
3. Anaerobic anaerobic digestion plant
- Made of stainless steel
- Volume 80 L
-electric heating jacket with insulation
-temperature sensor
- two industrial glass portholes with a diameter of 100mm
- 2 liquid supply taps
-1 nitrogen inlet for bubbling
-1 safety valve
- High level detector
- Bottom valve
4. Peristaltic pump for admixtures
- Adjustable pump 0-10L/min
- Continuous or pH-dependent operation possible (lime addition)
- 20L HDPE feeder trays
5. pH electrode
- Removable pH electrode
- Swing and isolation valves
- support plate for a beaker (calibration)
6. Temperature sensor type Pt 100
7. Recirculation pump
- Flexible variable speed impeller pump
- Flow rate: 0-40 L/min
8. Digital Flow Meter
- Technology: Electromagnetic
- Scale: 0.2 - 50 L/min
9. Treated effluent outlet
- Three-way valve
10. Sampling
- Effluent sampling
11. Biogas type
- Ventilation valve for the air of the methanizer
-Separator filter for gas conditioning
- Volumetric meter of the gas produced
12. Biogas analysis unit (optional GPBT61)
- biogas analyzer including a pellet drying unit and an industrial gas analyzer (ULTRAMAT23) for the measurement of CO2 and CH4 (0-100%).
The bench is installed on an aluminium profile structure equipped with 4 directional castors with brakes.
It includes an electrical box with all the necessary safety features (differential circuit breakers, thermal circuits, emergency stop button, disconnect switch, etc.). A 10-inch touch screen allows the machine and operating modes to be controlled. It also displays the measurements.