1. Semi-hermetic compressor accessible two-stage
Industrial type
Refrigerant: R454C
Condensing temperature + 35°C
Evaporating temperature -35°C
Cooling capacity: 6000 W approx.
2. Oil Separator
3. Air condenser
4. Liquid receiver with service valve
5. Brazed plate exchanger
6. Drier filter
7. Sight glass
8. An electromagnetic valve
9. Refrigerant flowmeter 40-400kg/h with bypass valve
10. Thermostatic expansion valve with external equalizer
11. Evaporator with forced ventilation of ceiling type. The evaporator is installed in a cold chamber of interior dimensions of 1230x1030x2030mm. The chamber is equipped with standard components (anti panic bar, valve ...). The load is simulated by electrical heater of 2000W with ON/OFF thermostat
12. Suction line accumulator.
13. Safety valve
14. High pressure, medium pressure and low pressure gauge with dual scale pressure temperature
15. Low pressure switch (control pump down)
16. Combined pressure switch HLP (safety)
17. High pressure switch (control of the condenser fan)
18. Oil differential pressure switch
Instrumentation:
The bench has the following instrumentation:
1. Thermocouple type temperature sensors (x13):
On the refrigerant circuit:
-compressor suction
-stage 1 discharge
-stage 2 suction
-compressor discharge
-condenser outlet
-exchanger inlet
-exchanger outlet
-expansion valve inlet
-evaporator outlet
On the air:
-condenser inlet
-condenser outlet
-evaporator inlet
-evaporator outlet
Structure:
all the components are assembled on a screwed anodized aluminium profile structure equipped with directional wheels with brake
Electric box:
The electrical enclosure is made according to the European standards. It includes safety elements such as GFCI, main switch, emergency stop button, earthing, start buttoning ...
It is equipped with a touch screen 7 "which displays the temperatures, the electric power consumed and the P&ID of the machine
A refrigeration temperature controller manages the operation of the unit, the regulation of the temperature of the cold room and the defrosting phases
2. Pressure gauges on the refrigeration circuit (x3):
-low pressure (compressor suction)
-medium pressure (intermediate stage)
- High pressure (compressor discharge)
3. Refrigerant Flow Sensor with Magnetic Transmission 40-400kg / h (x1):
4. Network analyser for measuring the electrical power consumed by the system (x1)