Power supply management of modules:
-a 16A 30mA circuit breaker with 5 sets of terminals for electrical supply of modules
- A 24 Vdc, 5 W AES safety power supply with integrated battery, LED indication and two changeover reporting contacts to the CMSI.
Conventional external fire safety controller (CMSI):
-CMSI conventional type 1
- 230VAC power supply
- integrated 12VCC7Ah battery
- 8 control lines for safety-actuated devices (DAS).
- 1 line for alarm sounders (DS).
- LED indication of line status.
- Keypad for line programming, testing and resetting.
Conventional type control and signalling equipment (ECS):
- Conventional ECS type 1
- 230VAC power supply
-Integrated battery
-4 detection loops
- 1 loop for self-contained audible alarm units (BAAS).
- 2 alarm sounder loops.
- Connection to the repeater panel.
- 3 reporting outputs (fire, general fault and auxiliary).
- LED indication of line status.
- Keypad for line programming, testing and resetting.
Conventional automatic detectors (DA), two types:
- Rate-of-rise heat detectors (x2).
- power supply 24vdc
-Operating temperature: 57°C
- Each detector is connected to a remote indicator (wiring to be completed).
- Optical smoke detectors (x2).
- power supply 24vdc
- Detector test aerosol supplied.
- Each detector is connected to a remote indicator (wiring to be completed).
Conventional manual call points (DM), two types:
- 1 red call point with resettable flexible element.
- 1 red call point with resettable flexible element and status indicator.
- Reset key supplied.
Signalling:
- 1 flashing red beacon.
- 1 alarm sounder (compliant with NF S32-001; 93 dB at 90°).
- 1 red call point with resettable flexible element and status indicator.
- 1 combined self-contained emergency lighting unit (BAES, for workplaces and buildings open to the public) +
self-contained residential emergency lighting unit (BAEH).
Actuators on premises:
-1 simulation fan for smoke removal (230VAC power supply)
- 2 fail-safe 24 V electromagnetic door holders with push buttons (fire-door simulation) and position monitoring contacts.
- Two doors with door closers.
Remote equipment:
- 1 remote control for BAES functions (test, standby, etc.).
- 1 push button with normally closed contact.
- A repeater panel for connection to the fire detection control and indicating equipment (ECS).
- 1 green manual call point to override door opening (security airlock simulation).
- 1 yellow manual call point to override smoke extraction (firefighter control).