1. A heat exchanger with concentric tubes
Equipped with several temperature measurements
2. Stainless steel tank of hot water
Tank capacity 70 L
3 kW electrical resistance for heating water
Low level probe
Safety thermostat
Temperature probe, thermocouple of type T
3. Centrifugal pump with magnetic drive
Maximum flow rate of 570 L/h
4. Hot water flowmeters with needle control valveand selector valve of the flowmeter used. Scales: 0.2-3 L/min and 1-10 L/min
5. Cold water flowmeters with needle control valveand selector valve of the flowmeter used. Scales: 0.2-3 L/min and 1-10 L/min
6. 6 thermocouples of type Tfor measuring the temperature of the hot water and the cold water inlet, at the middle and at the outlet of the exchanger
7. 4 Selector valves of co-current mode or counter-current
8. Filling valve of the hot water tank
9. Drain valve of the hot water tank
10. Inlet valve of cold water to connect to the network
11. By-pass valve