- Tubular heat exchanger for connection to BET 011
- heat transfert areas :
- -Inner tube:
-
Matrial: stainless steel
-Ø ext = 12 mm, Ø int = 10 mm
- Outside tube:
- Material: stainless steel
- Ø ext = 20 mm, Ø int = 16 mm
- mean transfer area: 270cm²
- cold water supply from BET 011
- hot water supply from BET 011
- Parallel flow and counterflow operation possible
Recording of temperature using BET 011
- 4 sensors: inlet and outlet
- 2 sensors: intermediate point cold and hot water
- T thermocouple type
- Input and output of each circuit of the exchnager