The bench is installed on an aluminum profile structure equipped with four braked-directional castors. It has an electrical box with a 30mA RCD.
1. Hermetic compressor average power 500W
2. Safety valve
3. Forced-Vent Air Condenser with Timer for Air Circulation
4. Service valves
5. Safety pressure switch HLP
6. Ball valve with connector Schrader
7. Filter + dryer 1/4"
8. sight glass
9. solenoid valve
10. expansion valve with internal equalization
11. Evaporator with forced convection power 495W
at dt 7K
12. Pressure regulating valve of evaporation KVP type
13. Suction line accumulator
The bench also includes:
-a power supply module with a differential circuit breaker and a 2P+ T socket for connecting the accessories (pump, recovering station ...)
-a digital thermostatic control box with probe in the chamber. The controller controls the compressor.
Two switches are used to stop the operation of the condenser and the solenoid valve (adjusting pressure switch).
-a cold chamber simulated by a cabinet. The cabinet door is equipped with an enthalpy diagram R290 with erasable surface (format A3).
-a storage area in the lower part of the frame with two access doors. A key lock is used to secure the storage.