1. The trainer is equipped with an electrical box including the safety (circuit breaker, AU, indicators ...) and the display of temperature measurements.
2. Open refrigerated commercial display case with shelves, light and temperature controller.
3. Hermetic piston compressor (operating between 0 to 6°C)
4. Forced air condenser with fan
5. Expansion valve
6. Forced air evaporator with fan
7. Manually reset safety HLP pressure switch
8. Structure in screwed aluminum profile movable on directional casters with brake
9. Integrated instrumentation:
Touch screen with measurement display:
- Compressor inlet temperature
- Compressor outlet temperature
- Condenser outlet temperature
- Temperature inlet regulator
- Temperature air inlet evaporator
- Temperature air outlet evaporator
- Compressor suction pressure (LP)
- Compressor discharge pressure (HP)
- Energy consumed.
- Instantaneous electrical power
10. Fault simulation
Failures are simulated from the touch screen, a screen page is accessible by code and allows to activate one or more failures.