1. 3 compressor unit:
-3 semi-hermetic compressors power 1.14kw at -28 ° C / 40 ° C with service valve
- each compressor is equipped with a HLP safety pressure switch
-LP and HP pressure gauge on each compressor
-Compressor N ° 1 with speed variation
2. HP manifold with safety valve, isolation valve and pressure gauge
3. Oil separation and recovery circuit:
- in-line oil separator
-oil return line with dehydrator, sight glass and pressure gauge
- oil tank with two sight glasses, a regulator and service valve
- oil level regulator on each compressor
4. Forced convection condenser power approximately 7.5KW with pressostatic variator
5. High pressure liquid line:
-steel liquid receiver with service valve
- dehydrator, liquid sight glass and pressure gauge
6. Evaporation line N ° 1 comprising:
-a refrigerant flowmeter
-a manometer at the inlet at the outlet of the evaporator
-an electronic expansion valve
-a forced convection evaporator placed in a cold room with internal dimensions 83x83x200cm with door, decompression valve and load simulation by electric heating. The wall thickness of the chamber is 100mm
-a non-return valve at the evaporator outlet