The bench is divided into two modules. Each module includes at least: 1. A power supply electrical box with white LED and a power supply breaker 2. A boiler: Boiler 1: Type: mixed, heating and instant DHW Heating: 1 direct start Burner: Natural gas with a power of 25 KW Fumes exhaust: suction cup Boiler 2: Type: Condensing mixed, heating and DHW micro accumulated Heating: 1 direct start and 1 start with three-way valve Burner: Natural gas with a power of 25 KW Fumes exhaust: suction cup 3. A mixer tap sink and siphon 4. A water supply circuit comprising a meter, a filter, an anti-pollution valve, a backflow preventer and a pressure manometer.
|
5. DHW circuit comprising two thermometers and two manometers (hot and cold water) 6. A heating circuit comprising a flow meter, two thermometers, a balancing valve, a differential valve and a manometer 7. A regulated heating circuit comprising a flow meter, two thermometers, a balancing valve, a differential valve, a manometer, a circulator, a three-way valve and a safety thermostat (only for the boiler 2) 8. A gas supply circuit comprising stop valves, a pressure manometer and a meter 9. A white magnetic board with erasable surface (display of the documentation of the boiler and reading of measurements) |