The bench consists of the following elements:
1. A floor-standing condensing gas boiler, power 23KW
2. A heating safety valve calibrated at 3 bar with manometer
3. A safety pressure switch lack of water
4. A flowmeter 160-1600L/h on the hot water of the boiler
5. A dial thermometer 0/120°C on the hot water of boiler
6. A three-way valve with servo electric motor installed in mixture
7. A flowmeter 160-1600L/h on the mixing branch of the three-way valve
8. A water pump 25-80 with pressure measurement kit
9. A dial thermometer 0/120°C on the hot water circuit towards the dissipation
10. An injection pot volume 12L with insulation valves, drain valve and air vent valve
11. A differential pressure valve