1. Electrical distributor 4/3 closed center
Part Number: AD3E01CM 24VDC
Central piston removed preventing normal operation of the drawer. Piston supplied for refurbishment
2. Non-functional 24Vdc coil
Ref D15 24VDC (M)
3. Pressure limiter on P
Ref AM3VMPC2
Mounted with a lower stiffness spring, simulating a broken spring, not allowing to limit the pressure on P. Original spring supplied for refurbishment
4. Double pressure limiter on A&B
Ref AM3VMABC2
Mounted with two lower stiffness springs, simulating a broken spring, not allowing to properly limit the pressure on A &/or B. Original springs supplied for refurbishment
5. Pressure reducer
Ref AM3RDP1C2
Piston removed not allowing to reach the desired pressure. Piston supplied for refurbishment
6. Dual flow limiter
Ref AM3QFABC
Fluid flow washer with Ø too large preventing to limit the flow on one of the outlets
7. Double-piloted non-return valve
Ref AM3UPAB1
Valve removed on one of the outlets not allowing to block the fluid